Electrical & Instrumentation Technician
Réf. 260921133132 · Né(e) en 1980 · Mahdia · Plus de 10 ans d'expérience

Coordonnées masquées — CV anonymisé par PMEBTP
Ma recherche
Je recherche tout type de contrat, dans toute la France, dans le Batiment.
Atouts et compétences
- Electrical & Power HV/MV/LV switchgear
- MCC & transformer testing
- Motor testing (IR
- winding resistance
- rotation)
- Cable installation
- glanding
- termination & testing
- Cathodic protection (ICCP & galvanic)
- Instrument calibration & loop checking
- Field instrumentation (PT
- TT
- FT
- LT
- control valves)
- DCS/PLC loop checking & commissioning
- Radar tank gauging (FMCW) & MSTT systems
- Fire & gas
- ESD/SIS function testing
- Hazardous area compliance (ATEX/IECEx)
- IEC standards (60364
- 61439
- 60947
- 62271
- 61511)
- ISO 9001:2015 quality procedures
- ITP/ITR execution
- FAT/SAT support & punch‑list closure
- NCR reporting & corrective‑action support
- As‑built mark‑ups & completion dossiers
- Project planning & coordination
- Team supervision & training
Langues
Arabic (maternelle), English (courant), French (courant), Italian (notions)
Permis
Permis B
Expériences professionnelles
E&I Technician
Employeur confidentiel
Conducted comprehensive E&I condition assessments on sewage pump stations and treatment plants; inspected MV/LV switchgear, MCC, transformers, cable trays, conduits and earthing; performed cable testing, generator set tests, motor tests; verified field instrumentation; compiled structured assessment reports with recommendations.
E&I Technician
Employeur confidentiel
Executed maintenance, repair and calibration campaign on three spherical LPG tanks; installed pressure gauges, transmitters, radar level gauges and multi‑spot temperature transmitters; replaced instrumentation cabling and performed loop verification; delivered calibration certificates and as‑built mark‑ups.
E&I Technician
Employeur confidentiel
Reviewed IFC documents, followed ITPs and MIRs, raised RFIs, performed MV/LV cable pulling and testing, installed cathodic protection, installed and tested transformer rectifiers, flagged NCRs and supported corrective actions.
E&I Technician
Employeur confidentiel
Contributed to Project Quality Plan, followed QA/QC schedule, managed material handling, coordinated installation packages, compiled FAT/SAT reports, installed conduit, cable‑trays, transformers, HV switchgear, UPS, grounding, and field instrumentation; performed calibration and pneumatic leak testing.
E&I Commissioning Technician
Employeur confidentiel
Supervised installation activities, performed grounding checks, erected and terminated process and safety instruments, supervised cable laying, pre‑commissioned E&I cables, calibrated instruments, commissioned diesel generators, LV panels, UPS systems, fire & gas systems and field instruments; established Modbus and PROFIBUS communications.
E&I Technician
Employeur confidentiel
Verified skid arrival against vendor drawings, checked nameplates, inspected skid for transport damage, performed motor megger tests, verified MCC interfaces, earthing and bonding, and inspected instrumentation installations.
Instrumentation Technician
Employeur confidentiel
Read and interpreted electrical diagrams; maintained hydraulic/pneumatic control panels; verified SSV/SDV solenoid function; performed motor terminations and testing; calibrated level, pressure and temperature transmitters; verified 4–20 mA loop integrity and HART communication.
E&I Technician
Employeur confidentiel
Installed cable trays, flow, temperature and pressure transmitters, and associated junction boxes; performed glanding and termination of instrument cables; pre‑commissioned E&I cables (IR and continuity tests).
Electrical Technician
Employeur confidentiel
Wired electrical cabinets and installed measuring instruments; installed cable trays and performed cable pulling, dressing, glanding and termination for lighting panels, DBs, junction boxes and control panels; performed IR and Hi‑Pot testing of power cables and transformer testing (vector‑group, BDV, turns‑ratio, etc.).
Electrical Technician
Employeur confidentiel
Performed IR and continuity testing of control and power cables; replaced the electrical control cabinet for the four ship engines; installed lighting, fire‑detection equipment and alarm systems in the control and engine rooms; repaired and reorganised wheel‑house equipment.
E&I Technician
Employeur confidentiel
Installed and calibrated flow, temperature, pressure, and level transmitters, vibration sensors, control valves, and MOV actuators; performed pre‑commissioning cable IR/continuity checks and witnessed grounding/earthing system testing.
Elevator Technician
Employeur confidentiel
Assembled, installed, repaired, and maintained elevators and stairlifts; adjusted safety controls, counterweights, and door mechanisms; performed scheduled preventive maintenance on construction sites.
Formations
Bac +2
Centre Sectoriel de Formation en Électronique, Sakiet Ezzit, Sfax
Industrial Electronics Technician – Brevet de Technicien Professionnel
Bac
Lycée 18 Janvier, Jebeniana
Baccalauréat – Section Technique